what is nomial clear width

RELATED FAQS

Question
Answer
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
Pocket pivot hinges are mainly used in cross corridor applications where clear opening width is a factor. For frames, pocket pivot hinges are a special hinge options which must be spe...
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, glass light designs and hardw...
1-1/8" at door face, 2-3/8" at widest point, 3-1/2" depth, with 1/8" thick walls.
The difference between the L and N escutcheons is the size and how they are manufactured. L Escutcheon: 8" x 1 3/4" x 7/16" (203mm x 44mm x 11mm) Cold-forged brass, bronze or stainless steel ...
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
"PUSH SIDE" application:    Minimum 52" wide pair,  with neither door being less than 21" wide.   "PULL SIDE" application - For Product Shipped...