Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
WHAT IS AFIC
”
RELATED FAQS
Question
Answer
Are Securitech 8400 series lock available on the Paladin series door?
Resolution:
The following Securitech products have been tested and approved for use on Steelcraft Paladin doors:5300 series devices- 3 point surface and concealed devices7300 series devices- 3 point surface an...:
GLAZING BEAD
Resolution:
Definition:Glazing Molding, Glass Stop; Removable Stop:
What is the maximum glass size available on the T-Series door?
Resolution:
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...:
What does a blinking TROUBLE LED (D1/D2) mean on my PIM400-TD2?
Resolution:
a) One blink of the TROUBLE LED means the AD400 on this channel has low AA batteries. Install fresh batteries. b) Two blinks of the TROUBLE LED means the AD400 on this channel is not communicating...:
What is the difference between the L-Series and H-Series doors?
Resolution:
The L-Series doors are designed for virtually all construction requirements in commercial building applications. They have also been tested and approved for uniform wind load per ASTM E330. ...:
What is the L Series inside lever mounting plate part number?
Resolution:
The inside lever mounting plate part number is L283-031.:
What is the standard undersize for Steelcraft transom panels?
Resolution:
Steel transom panels are available: 1 3/4" thick panels - supplied in L-Series (L20, L18 or L16-Series) laminated construction. Recommended down sizing is as follows: Without Transom Bar 3...:
What is the difference between normally open and normally closed?
Resolution:
In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by o...:
What are the installation tolerances for hollow metal frames?
Resolution:
Industry standards for hollow metal frames installation tolerances have been developed by both the SDI (Steel Door Institute) and HMMA (Hollow Metal Manufacturers). Both standards are based on th...:
What is maximum width, height and weight for IVES butt hinges?
Resolution:
Butt hinges can be used on doors up to 4' wide and 200 pounds. There is no maximum door height. However, an additional hinge must be installed every 30" when exceeding a 7' d...:
What is the maximum door size for ITS/WHI fire rated doors?
Resolution:
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...:
Why does the the 9954 mullion have taller bottom fittings than the 4954?
Resolution:
Bottom mounting fitting on 9954 is taller than 4954. The taller bottom fitting is required for a fire rated application.:
What fire ratings are available on DW-Series Borrowed Lights?
Resolution:
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...:
What is the maximum size of a UL fire rated three (3) sided frame?
Resolution:
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame:4' 0" X 10' 0" single door opening8' 0" X 10' 0” double door openingMU-Series frame...:
What is the difference between galvanized and galvannealed steel?
Resolution:
Galvannealed and galvanized steel are zinc coated at the steel mills and are designed for rust and corrosion resistance. Both steels are passed through a hot dip coating process for rust prevention...:
What is the maximum size of a ITS/WHI fire rated three (3) sided frame?
Resolution:
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes:F and FN-Series:4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsMU-Series:4' 0" X 9' 0" si...: