Chexit devices shipped prior to 8-24-2015 with solenoid driven could cause the Von Duprin CX solenoid to pull and drop and sound the alarm with solid LED or no LED light after the rear...
The EPT2 has (2) 18 gauge wires and the EPT10 has (10) 24 gauge wires.
Even though they are 18 gauge or 24 gauge wires they are special high stress, high flex, & high current wires specifically u...
The PIB300/PIB301 should be located as close as possible to the Access Control Panel. Do not exceed 500 feet.
Wiring distance from the PIB300/301 to the AD300/301 locksets may be up to 1000 feet (18AWG) for Power and up to 4000 feet (24AWG) for the RS485 data lines.
See the User Guide instructions in the links below
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
Product Ordered after 7/10/2012 - Product identified by label on QEL motor
You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor.
You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices. The attached ta...