Use the 575-2 strike with 9975 device on a pair of 1 3/4" thick doors with overlapping astragal mounting on the exterior of the active door. The strike lip has been cut off to eliminate any interfe...
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.
The standard Von Duprin mechanical or electrical 98/99/33/35 exit devices can not be converted to a CX98/99 or CX33/35 device. Von Duprin CX98/99 or CX33/35 has a different base p...
Part numbers for Schlage and Falcon cylinders for Von Duprin devices are listed below. (KIL = Key In Lock) SCHLAGE   Mortise Rim KIL ...
FALCON   Mortise Rim KIL Conventional 986 x #4 cam 951 A23165-02 Small Format Housing C987...