what door levers are ada compliant

RELATED FAQS

Question
Answer
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
See the Levon lever below, Figure 1. Figure 1: Levon dimensions
  The door face to lever tip distance is 1 3/8"
Falcon manufactured an EZF101 which was a large plate with a recessed lever for use in elevators.  This item is no longer available.     
The lever return distance (tip of lever to door face) on the Jupiter lever design is approximately 1-3/4".
The square block is probably the springcage assembly, L283-040.  This component has an internal spring to keep the lever in the horizontal position.
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Order the 09-900 with the XB11-720 option.
The thumbturn measures 2.085" in length and is ADA compliant.
All functions except L9463 and L463: Add L583-363 to the part number 09-509 L583-363 for the turn only or L9453 07L 626 L583-363 with a lock The L583-363 part number is an option and can not...
8103EZ and 9103EZ have 2 1/2" clearance the other pulls have 1-1/2" clearance. Check with your local code for clearance required.