What does RPD strike prep mean
”
RELATED FAQS
Question
Answer
STRIKE PREP
Resolution:
ASA, ASA-48, ASA-60, ASAR, ASA-SP, ASAV, CYL, CYL-48, CYL-60, CYLR, CYL-SP, CYLV; Prep per Template, SPL:
CYLR
Resolution:
Strike Prep, 2 3/4" Door Strike Prep with lip and RPD reinforcements; ANSI A115.2, Door Strike Prep:
ASAR
Resolution:
Strike Prep, 4 7/8" ASA Door Strike Prep with lip and RPD reinforcements; ANSI A115.2, Door Strike Prep:
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
What is included in the 39-030 rabbeted latch and strike kit?
Resolution:
39-030 can be used on the A, AL, B250, B500, B600, D, ND, S products. This kit adapts a square corner latch and a 2 3/4" high square corner strike to 1/2" rabbeted door and frame preparation. :
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...: