Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
what does "Cush" mean?
”
RELATED FAQS
Question
Answer
What is the difference between a 4110-18, and a 4110-18 CUSH drop plates?
Resolution:
The 4110-18, and 4110-18 CUSH drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...:
When did the 4111 Cush arms become non-handed?
Resolution:
This engineering change did affect the templating of the closer. The stop in the shoe is slightly larger than the original handed cush shoe. The new non-handed arm template locates the closer and s...:
What is the part number for the Spring Cush block?
Resolution:
The part number for the Spring Cush block assembly is: model number-3080. EXAMPLE: 4110-3080:
Can you mount a 4040XP CUSH with a Flush Transom frame?
Resolution:
The 4040 XP CUSH/EDA can be mounted on a Flush Transom frame by using a -419 Flush Panel adapter.:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
What is the maximum degree of opening you can template a 4110 Cush closer?
Resolution:
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates.The 4110 if ordered by ST-3220 will allow templating to 135°:
Is the Cush Shoe Support (-30) the same for all of LCN closers?
Resolution:
For LCN Cast Iron Closers, the 4050A, and Falcon SC closers it is (1 3/4") wide, (1 1/2") tall and (1 1/2") deep For 1250 and 1450 LCN Alum body Closers it is (2") wide, (1 1/2") tall and (1 1/2"...:
Is the EDA or Cush arm with threaded studs still available?
Resolution:
ST-3195 is used to obtain the old style EDA or Cush arms which were assembled with threaded studs so that you could take apart the arm assemblies. Our current standard EDA and Cush arms are rivet...:
SPRING CUSH ARM
Resolution:
SCUSH,:
HOLD-OPEN CUSH
Resolution:
HCUSH, PA Mount, Parallel Arm Mount:
SPRING HOLD-OPEN CUSH ARM
Resolution:
SHCUSH,:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
Can a Cam Lift hinge be used with LCN closers?
Resolution:
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or T...:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
What does BSS and CSS stand for?
Resolution:
BSS means - Blade Stop Spacer. A -61 for example would be used after the series of the closer being used.CSS means - Cush Shoe Support. A -30 for example would be used after the ser...:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
What are the 1460 closer arm options?
Resolution:
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...:
Can you mount a 4041 Cush arm with a EDA arm template and get 180 degrees opening?
Resolution:
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.:
Can a 4040 open to 180°?
Resolution:
The 4040/4040XP closer mountings have the following maximum opening degree templating: The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening. The 4040/4040...:
Can you convert a 4041 Cush arm to a 4041 HCush arm and use the same templating?
Resolution:
The 4040XP/4041 Cush and HCush (Hold Open Cush) use the same instructions / template.:
What is the part # for the 4040 HCush arm?
Resolution:
The part number for the 4041/4040XP HCush arm is 4040XP-3049CNS.:
How do you order a 4110 hold open spring cush arm only?
Resolution:
The 4110 hold open spring Cush (Spring H Cush) arm part number is 4110-3049SCNS.:
Are there special brackets needed when using the 4110 series with a coordinator?
Resolution:
When using the 4111 with a bar style coordinator MB-mounting brackets ordered from IVES are required. The brackets wrap around the coordinator to provide a surface for mounting the parallel arm ...: