what current should an ad-series
”
RELATED FAQS
Question
Answer
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Resolution:
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...:
Will the Schlage CO or AD trim work with the Falcon 25V device?
Resolution:
The Schlage AD/CO trims are not compatible with the Falcon 25-V device due to the main cam on the device rotating the opposite direction for a given hand compared to the AD/CO trims output dri...:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
What is the power draw of a Senior Swing series operator?
Resolution:
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/...:
Are the legacy Von Duprin PS873 and the current PS900 power supplies filtered and regulated?
Resolution:
The Von Duprin PS873 and PS900 series power supplies are filtered and regulated.: