Question
Answer
Can I get a Senior Swing with a reduced opening force gearbox?
Resolution:
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual opening force, and reduced force "RF" required 11 lbs of manual opening force. All S...:
What is the minimum clear opening width required by ADA on a single door?
Resolution:
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...:
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
How narrow of a door can a 98/9927 device be mounted?
Resolution:
Minimum door opening on double door with 98/9927 should be 25.5" and single door is 25.65".:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
What is the minimum door opening width for mounting the 4640 or 4630 on a double door?
Resolution:
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...: