What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
Does Schlage or Falcon offer a backset greater than 5"?
Resolution:
Only the Schlage D-knob and ND products are available with an extra long backset. The part number for backsets over 5"-42" is XC03-069, this part will ship as an extension link to b...:
What backsets are available on Schlage and Falcon locks?
Resolution:
SCHLAGE locks are available with the following backsets: Lock Series Lock Type  ...:
What is the standard backset on a Falcon B lock?
Resolution:
The standard backset for the Falcon B Series is 2-3/4". A 2-3/8" backset is also available if specified.:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
Is the 1 3/4" backset still available for a deadbolt?
Resolution:
This product is obsolete and no longer available. At one time a 1 3/4" backset for the old B100/B400/B500 deadbolts was available.:
What backsets are Hospital latches available?
Resolution:
Hospital latch available backsets: 2-3/4", 3-3/4", 5" or 7":
When using the 98/99 rim what backset should be used when using with 6300 strike?
Resolution:
The backset is the same for the 6300 surface mounted electric strike as it is when using the 299 strike. There should be 3/16" gap from the face of the device and the face of the strike.: