Question
Answer
Where can Von Duprin 6300 electric strike installation instructions or templates be found?
Resolution:
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached https://us.allegion.co...:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Does the Von Duprin E996L trim require the NL drive screw be installed into the device to function properly?
Resolution:
Von Duprin 98/99 NL drive screw is located in back of the 98/99 center case assembly. NL drive screw should be left in with trim lock slide plate in up position in the 98/99 exit device with E99...:
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :