Question
Answer
Can electrified hinges be used on QEL devices?
Resolution:
The electrified hinge can be used on QEL exit devices.:
Where is common cutout for Von Duprin EPT prep in Ives 224 Continuous Hinge?
Resolution:
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template. 112HD/224HD continuous hinge Center line of EPT to top of the door 83 inches 30 inches 85 inches 32 inc...:
Are EPT preps available on the Paladin Series door?
Resolution:
EPT power transfer preparations are available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door&...:
Which electrified hinge is required or recommended for use with EL devices?
Resolution:
Recommend at least a 4 wire hinge and double up the wires for EL application.:
What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
Do we offer HD-QEL?
Resolution:
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...:
Why is the 2Q option board required to operate Von Duprin QEL devices?
Resolution:
Communication takes place between the 2Q option board and the Von Duprin QEL exit device. If this communication does not occur then the device will not retract. The 900-2Q board is not ...:
Is the SD option available with Von Duprin QEL 98/99 exit devices?
Resolution:
SD option is available and is also standard with Von Duprin 98/99 rim and vertical rod exit devices but not available with mortise device.: