Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
von duprin hh prefix
”
RELATED FAQS
Question
Answer
How should a Von Duprin exit device be written out for ordering?
Resolution:
To order Von Duprin exit devices, reference the "How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website. Choose "Cata...:
Do 25 series exit devices have a hurricane rating available?
Resolution:
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.:
Can the deadlocking feature be added to a 24-R in the field?
Resolution:
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt. Parts to the F-24R center case & cover can b...:
Why would 24-R device pop open when jiggled back and forth?
Resolution:
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt would resolve the issue. Parts to the F-24R center case...:
Can a 55 or 88 series device have a request to exit switch?
Resolution:
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...: