Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
Can the XX-V, 19-V, 24-V or 25-V extension rod be used on the bottom rod?
Resolution:
The extension rod could be used either on the top or bottom rods.:
Surface vertical rod exit device
Resolution:
Exit device with surface applied rods connected to top and bottom latches.:
How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Can I use an AD or CO - 993 Exit Trim with a Von Duprin 98/99 Concealed Vertical Rod exit device on a wood door?