Von duprin electrical options
”
RELATED FAQS
Question
Answer
What power supply is needed for EL devices?
Resolution:
You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board will power 1 or 2 devices that do not require timing from pow...:
Is a rectifier needed to change AC to DC on Von Duprin 6000 series electric strikes?
Resolution:
The strike will always be DC. By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.:
Are the wires on a Von Duprin 6000 series electric strike polarized?
Resolution:
The wires on 6000 series electric strike solenoid are non polarized.:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
Is there a Von Duprin conversion kit to change mechanical to electric latch retraction EL in the field?
Resolution:
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...:
What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
What questions should be asked to determine which Von Duprin 6000 series electric strike I have?
Resolution:
See Catalog to identify specific model: Von Duprin Electrical Security Products and Accessories Catalog:
Where can Von Duprin 6300 electric strike installation instructions or templates be found?
Resolution:
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached https://us.allegion.co...:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Will the 6300 work with the 55 rim?
Resolution:
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.:
How can the Von Duprin 4854 mullion be ordered when using the 6300 electric strike?
Resolution:
:
What gauge wire is needed for CX red and black power wires?
Resolution:
For Product Shipped prior to 8-24-2015 with solenoid and EPT or Door Loops: a. 0-100 ft, use #14 Gauge Wire ...:
Does the Von Duprin 6121 electric strike work with the Von Duprin XP exit device?
Resolution:
Von Duprin does not recommend using XP98/99 devices with any electric strike. Von Duprin recommends using the standard 98/99 rim device. :
Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
Resolution:
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00.:
Are the Von Duprin 6000 series electric strikes rated for continuous duty?
Resolution:
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...: