Question
Answer
What is the part number for the E996L rim conversion kit?
Resolution:
The 050672 is the part number for rim or vertical rod device and 050673 for the mortise device.:
Can you convert the EL33A/35A or EL98/99 series exit device to the QEL device?
Resolution:
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used. ...:
How do you change the Von Duprin 990TP trim to NL function?
Resolution:
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...:
What is the part number for hex dogging conversion kit for a 99 device?
Resolution:
The part number for hex dogging conversion kit for 99 devices is 050114.:
What is the part number for the offset link for 98/9947WDC devices?
Resolution:
Offset link for 98/9947WDC is not available by itself. You need to purchase the 98/9947WDC conversion kit, 050134.:
Can Von Duprin GBK's be stacked up to clear a 9/16" glass bead on a fire door?
Resolution:
You can only use one GBK Glass Bead Kit (1/4") per device on fire rated openings. Glass Bead Kit is for use on doors with raised glass beads.:
How do I convert the Von Duprin 360L control from nightlatch to classroom function?
Resolution:
To convert the Von Duprin 360L/TL from nightlatch to classroom or from classroom to nightlatch invert mortise cylinder cam.:
Is there an EL conversion kit for the Falcon 2390 exit device?
Resolution:
There is no EL conversion kit for a 2390, the device will need to be replaced.:
What back plate conversion kit is required for the 88 with the 373L trim?
Resolution:
Attached tables provide the back plate conversion kit for all 88 series Exit devices. 88 Back plate conversion Chart :
Will there be 900-2Q boards for warranty purposes now that the QEL'S do not require the boards?
Resolution:
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board. :
Is the Von Duprin Chexit part number 050228 a module or a kit?
Resolution:
The circuit board is sometimes referred to as a "module" in the field.:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
What is the part number for QEL94/95 inpact conversion kit?
Resolution:
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required: Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...:
Does Schlage offer ND conversion kits to convert to Classroom Security function?
Resolution:
For all available ND Series Conversion Kit part numbers, click here.:
Which keyed removable kit is used with a 4754, 4854, 9854, or 9954 mullion?
Resolution:
The Von Duprin 4754, 4854, 9954, and 9854 mullions can be converted or ordered with key removable option. KR54-F kit is the conversion kit to convert the above mullions to key removable mullion.:
What is the current draw of a Von Duprin exit alarm kit ALK?
Resolution:
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
Can you field install a RX switch on the 24/25 device?
Resolution:
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...:
Can you use a CD conversion kit on a 22 device?
Resolution:
Cylinder dogging CD is not available with 22 series exit device.:
Does EL or QEL conversion kit for Von Duprin exit devices contain mechanism cover plate?
Resolution:
The conversion kit does not contain a new mechanism case cover plate. If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cove...:
How does the Von Duprin 88TP convert to an 88L?
Resolution:
Followings are the steps to convert the Von Duprin 88TP to 88L device. Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing. Recomme...:
What is the part number for the 99L to 99L-2 kit?
Resolution:
Format for ordering double cylinder (-2) and double cylinder with security indicator (-2si)(device) (fire rated)(-2 or -2si)(conversion kit)(finish)(handing) Examples:98/9927-F-2-Conversion Ki...:
Does the Von Duprin CD kit include the machined cover plate for the cylinder?
Resolution:
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...:
Is there a Von Duprin conversion kit to change mechanical to electric latch retraction EL in the field?
Resolution:
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...:
What is the part number for the 6000 series electric strike 24VDC solenoid?
Resolution:
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below. Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 1...:
Does Von Duprin offer a classroom security option with visual status indication?
Resolution:
Von Duprin offers two options: The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLO...:
Do we offer HD-QEL?
Resolution:
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...:
Does a Von Duprin ALK kit come with an RX switch?
Resolution:
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.:
Is there a Von Duprin delay egress Chexit conversion kit?
Resolution:
There is no conversion kit for Von Duprin Chexit device. If delayed egress Chexit device is required, the entire device must be replaced.:
If I convert from the Von Duprin 88 K (88 rim with 880K trim) to the 373 L trim is a new back plate required?
Resolution:
No, the back plate for 880K-knob trim is the same as for 373L-lever trim. However, since 373L is a narrow style trim, an 889 cover plate is required: part number is “889.finish”:
Can you cut the EL conversion kit - 3' base plate to fit a 30" 9947 device?
Resolution:
You need to order the EL98/9947 or 3' EL conversion kit. This will fit on 28 1/8" minimum door opening on two vertical x vertical rod device doors.:
What parts are needed to convert an 88TP to 88NL?
Resolution:
To convert the 88TP to 88NL, device needs a correct back plate conversion kit, part number 050101 and a new 880NL trim.:
What is the part number for the Von Duprin maintenance kit?
Resolution:
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...:
What is the part number for the HD EL conversion kit for Von Duprin devices?
Resolution:
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.:
How to convert the Von Duprin E996L trim from FS fail safe to FSE fail secure?
Resolution:
The E996L will ship FS fail safe from the factory if you don't tell us, You can order either FS/FSE. Can be converted to FSE fail secure. To convert the 996L to E996L (fail safe or fail secur...:
Is there a conversion kit to add Electronic Dogging (ED) or Electric Latch Retraction (EL) to a 1690 or 1790 in the field?
Resolution:
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate base...:
Is there a conversion kit to electrify the LP373L lever control?
Resolution:
There is not a conversion kit to electrify the LP373L lever control. You need to order a complete E-LP373L-BE control through Engineering Specials.:
What cylinder is used for the Von Duprin -2 double cylinder function?
Resolution:
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2.Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an&n...:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
Can the Von Duprin EL option be added to any existing 98/99 device?
Resolution:
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. :
How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Is there a conversion kit to make 94/95 devices into a QEL?
Resolution:
Yes. Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish Optional LX switch &nbs...:
Can a Von Duprin 996L trim be converted to E996L trim?
Resolution:
A E996 conversion kit is required to convert the 996L/L-BE trim to E996L/L-BE electric trim. 050672-00 is the electric conversion kit for 996L rim or vertical rod exit device. 050673-00 is the ...:
Does Von Duprin have any current trim that can be provided to work with the 44 series device?
Resolution:
The 880 series trim will work with the 44 series device.:
How is the Von Duprin LX kit different than the EL - LX kit?
Resolution:
The Von Duprin LX kit would have a rod included in the kit. The EL-LX switch kit does not include the rod as the EL dogging rod is used.:
How do you convert the Von Duprin 370 series controls to NL or night latch function?
Resolution:
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...:
Do we have conversion instructions for the E996 when shipping conversion kits?
Resolution:
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.:
Can the Von Duprin 9947 metal door device be converted to the 9947WDC wood door device in the field?
Resolution:
The Von Duprin 9947 metal door device can be converted to the 9947WDC wood door device by purchasing conversion kit number 050134-XX. This conversion kit is only for the panic version only. Fire ...:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Can the EL or QEL conversion kit be used on the old Von Duprin 33/35 exit device?
Resolution:
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003). At one time, the obsolete black EL ...: