von duprin bottom rod length
”
RELATED FAQS
Question
Answer
How long are the rod lengths for the 25-V?
Resolution:
The top and bottom rod itself is 35" long standard.:
Can you order 8827L-F less bottom rods?
Resolution:
Von Duprin will not supply the 8827-F less the bottom rod because the device has never been UL tested less bottom rod.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What parts do I need to add to the bottom rod of my existing Von Duprin 8827 LBR exit device?
Resolution:
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike:
What parts are necessary to add the bottom rod/latch/strike to a 98/9927-LBR/LBR-F (less bottom rod) device?
Resolution:
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device. Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish) Bottom Latc...:
What would keep the vertical rod exit devices top latch from being held retracted in the open position?
Resolution:
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...:
Is the 2227 panic exit device available LBR?
Resolution:
The Von Duprin 2227 or 2227-F exit device is available less bottom rod. Specify 2227-LBR or 2227F-LBR for fire.:
Can you do LBR on a 98/9947 WDC?
Resolution:
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating. If not fire rated simply omit the bottom rod but be aware that your...:
Will the 25-C series rods and latches work on the old 18-C?
Resolution:
The internal rods and latches for the 25-C carried over from the older 18-C device so they can be used interchangeably.:
Why would an EL1690 retract the rods but not hold them?.
Resolution:
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Can the XX-V, 19-V, 24-V or 25-V extension rod be used on the bottom rod?
Resolution:
The extension rod could be used either on the top or bottom rods.: