Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
vestibule closer problems
”
RELATED FAQS
Question
Answer
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
What would cause my door closer to try and open the door instead of closing it?
Resolution:
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...:
What would cause an ME Series closer (2310ME/4310ME/4410ME) to pop back into hold open as it is closing?
Resolution:
This condition can be caused by the "closing speed adjustment" being regulated for a fast closing speed. Try adjusting the closing speed to slow down the closing of the door. If that does not corre...:
Which of the Pneumatic operators uses the same cylinder?
Resolution:
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.:
Is the 4041/4040XP and the 4040SE cylinder body the same?
Resolution:
The 4041/4040XP and 4040SE closers cylinders are "NOT" the same. The 4041/4040XP cylinder has an adjustable size 1-6 spring. The 4040SE cylinder has an adjustable size 2-4 spring. The 4041/404...:
What is the difference between a regular arm and the Rw/PA arm?
Resolution:
The Rw/PA arm is simply a regular arm that is packed with a 62PA (parallel arm) shoe, which will allow a (Tri-Pack) closer to be mounted in a regular, top jamb, or parallel arm application.: