utility room lock
”
RELATED FAQS
Question
Answer
Why does the Schlage Utility Software application display the error message "E201 - This device is not connected?"
Resolution:
The E201 message can be ignored and all normal SUS and lock functions will be maintained. Click "OK " and continue. Update the Schlage Utility Software (SUS) to version 4.6.0 or highe...:
How do I program Locknetics CM / CL legacy locks with the Schlage Utility Software (SUS) and Hand Held Device (HHD)?
Resolution:
- With the CIP NOT inserted and the Schlage Utility Software (SUS) running o Enter the Master Programming PIN or Present Loc...:
Can an 18-R-L be converted to L-NL function in the field?
Resolution:
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).:
Old 1981 Schlage Lock Service manual.
Resolution:
The 81 service manual can be found here.:
Does Schlage make a mortise lock that the lever on either side retracts the latch and a key on either side retracts the deadbolt?
Resolution:
The L9466 Store/Utility Room lock can provide this functionality. Operation: Latchbolt retracted by knob/lever either side. Deadbolt thrown or retracted by key from either side. When the deadbolt ...:
L9466
Resolution:
Storeroom/utility room lock - Latchbolt is operated by knob/lever from either side. Deadbolt is operated by key from either side. - Caution: Double cylinder locks on residences–or on any door in an...:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
What is the difference between Night Latch (NL) and Class Room function?
Resolution:
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...:
What are Overhead Concealed door closer?
Resolution:
Overhead Concealed door closers are used to provide a more aesthetic look to the opening. Concealed in either the frame or the door Offer the ability to be adjusted to maintain...:
Is there a way to clone a failed PIM400 so it could be replaced without having to re-link associated locks?
Resolution:
It is currently not possible to clone an AD-Series PIM400.:
Can the low coin cell Nuisance delay be Disabled on a CO200?
Resolution:
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.:
The Hand Held Device (HHD) or Schlage Utility Software (SUS) will not connect to the CO200?
Resolution:
Make sure the HHD/SUS is set to USB communication by checking the small icon right of the "No Device Connected" message. The symbol should be a USB symbol when working with USB enable product...:
What is a lock function?
Resolution:
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
What is the SUS feature "Device Template"
Resolution:
See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...:
What is the Multi Point LM9300 Series?
Resolution:
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks...:
What ligature resistant trim is available on the ND or L9000?
Resolution:
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...:
Does SUS (Schlage Utility Software) run on the HP IPAQ PDA?
Resolution:
The SUS (Schlage Utility Software) will not run or work on the older HP IPAQ PDAs. The older HP IPAQ PDAs run CEUplink to interface and program legacy locks. The SUS (Schlage Utility Software) will...:
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
Do I have to couple each lock with the HHD/SUS after the coupling password is changed or updated?
Resolution:
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...:
Can the AD-Series and CO-Series magnetic card credential readers be set to read data from different magnetic card tracks?
Resolution:
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...:
Why do I get error message "E701 - Programming Lock Failed" on my Hand Held Device while programming an AD lockset?
Resolution:
Update your lockset using ADFwPkg 2.19.0 or higher. This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.:
What replaced the D400 series or the D800 series?
Resolution:
Part compatibility (Old vs new): With the exception of the cylinder, most of the parts are neither backward nor forward compatible. This includes the deadbolt. The cylinder mechanism for al...:
Are ND locks available in 629 or 630 finishes?
Resolution:
The AL and ND locks are not available in any stainless steel finishes. The only option is either the 626 satin chrome or 625 bright chrome.:
What versions of Microsoft Windows are compatible with Schlage Express version 4.4.2?
Resolution:
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...: