unequal pair doors Rim device
”
RELATED FAQS
Question
Answer
Can a Senior Swing 9550 be mounted on an unequal pair of doors?
Resolution:
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application - For Product Shipped...:
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
What strike is used for a pair of doors with a Dor O Matic Rim device x Flushbolts on inactive door?
Resolution:
The STK45 strike is used on the inactive door leaf.:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
What strike do I use with a pair of 22 rim device without a mullion?
Resolution:
The 1609 strike can be used on an inactive door with 22 rim device. NON-FIRE RATED doors only. :
Why does the auto operator not open the door when installed with a Chexit?
Resolution:
Chexits are NOT electric latch retraction devices, therefore the latch will not retract and allow the opener to swing the door open. Chexits block and unblock the latch. In order for a Ch...:
How do you order a Senior Swing header for a 2810 on one leaf and a 2010 on the other?
Resolution:
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors. Both units contained within the same Senior Swing header. To order a paired operator with a 2810 o...: