Yes. Remove the receiver from the operator. Remove the transmitter from the actuator button. Attach 1 wire to the NO (normally open) contact on the actuator switch, and another wire to the COM (com...
To convert a hard wired actuator button to a wireless actuator button you will need the following components: An RF transmitter. The 8310-844 transmitter for the (4-1/2" or 6" round, and the ...
To convert an RF actuator button to a hard wired actuator button, simply remove the RF transmitter an connect the hard wiring to the "Common" and "Normally Open" terminals on the the switch.
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the s...
Actuators are not included with a 4600 Series operator.  Due to the numerous styles, they always need to be ordered separately.
On average, the battery life on the wireless actuators will be 9 months to 1 year for most installations. Extreme (cold) conditions may reduce battery life.
Hardwired and RF actuators can be used together on the same operator. The hardwired switch and the RF receiver both provide a N.O. contact to the operator.
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-856 RF ...
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired -  831...
The 8310-865 RF receiver can have up to 100 transmitters programmed to it.
23848385 is the part number to order for the COM400 radio board that has the MCX jack for the optional RF antenna. It is shipped in the PIM400 and WRI400 so if needed for the wall mounted module yo...
The only difference between the COM400 in a door lock (AD400) and the COM400 in a wall mounted interface module is the MCX jack, which is provided for the optional remote RF antenna when needed o...