TRIM FUNCTION ON DELAYED EGRESS

RELATED FAQS

Question
Answer
Click here to watch a brief overview video of Chexit on the Allegion product support YouTube channel.
The Von Duprin Chexit device will not automatically rearm itself after a fire alarm clears.  After a Fire Alarm has triggered the Von Duprin Chexit device, the device must be manually reset&nb...
We no longer offer a delay egress board in the P900 series power supplies.
The delay egress is controlled in the exit device (Von Duprin Chexit), the magnetic lock, or other locking device.
The Von Duprin Chexit-BOCA has special software. Following is the function of this software: When Chexit device push bar is pushed and goes into alarm it will release in 15/30 sec...
The CX (Chexit) is the delayed egress option for the 98/99 series or 33/35A rim device. The device will create a 15 second delay with audible alarm when an unauthorized person tries to ex...
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-25 Series can perform a delayed egress by using the DE5300 controller, power supply, ...
A thumbpiece, knob or lever trim left in the unlock position would be locked when the Chexit is armed and unlock when the Chexit device is disarmed. To keep the outside trim in the lock p...
Device would be ordered as a 25C-C as of June 2012. C nomenclature is for the Cylinder. 
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...
Inside cylinder locks and unlocks the outside trim, such as thumb piece, knob or lever.  Outside cylinder functions as an NL when inside cylinder locks the outside trim.Double cylinder fe...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as se...
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...
No, only via DIP switch 8 and/or the aux input.
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...