Question
Answer
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What power operator is recommended/used for occasional activation with mainly manual traffic?
Resolution:
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
What would cause a Senior Swing to open only 10 degrees and then close?
Resolution:
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position. Unit will never learn opening nor function pro...:
What is the minimum and maximum reveal for a 9500(IQ) Series Senior Swing operator?
Resolution:
The 9542(IQ), 9553(IQ), 9563(IQ) surface mounted Senior Swing(IQ) with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10".The 9542(IQ), 9553(IQ), 9563(IQ...: