tl trim installation instructions

RELATED FAQS

Question
Answer
This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key. 
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
Dezigner Trim – This unique and patented glass trim has been designed to closely simulate trims installed in wood doors and is factory: Supplied recessed into the door face, to provide a neat f...
Flush Mounted Steel Trim for Insulated glass – Designed for 1” thick insulated glass. Recessed into the surface of the door face Accommodates 1" (25 mm) thick glass. When installed, fastener...
Overlapping Steel Trim (also refer to as conventional steel trim) – This trim is the typical glass trim supplied by most hollow metal manufacturers. Surface mounted on the door face. Accommo...
Flush Mounted Steel Trim – This trim is similar to Overlapping Steel Trim but is factory supplied recessed into the door face and is available for 1/4” glass. Glazing stops are screw attached, fast...
 Basic glass trim details:
The L283-150 is a modified mounting plate to allow a user to only install trim on the inside of the L9000.  For installation and door prep requirements, see the install sheet.  Add...
To convert the Von Duprin 360L/TL from nightlatch to classroom or from classroom to nightlatch invert mortise cylinder cam.
Verify the door thickness is 1 5/8" or greater per the pricebook.  Thin doors will force the clip off the housing.  If door thickness is correct then replace the product as needed.