Answer
Do Steelcraft PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements?
Resolution:
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC 500...:
What anchors are used in FEMA Tornado Resistant openings?
Resolution:
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is a Cam Lift Hinge?
Resolution:
Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...:
What are the maximum door width and height sizes?
Resolution:
Maximum nominal (overall) single door sizes are as follows:L-Series (Laminated Door)20 Gage = 3’ 0” wide X 8’ 0” high18 Gage = 4’ 0” wide X 10’ 0” high16 Gage = 4’ 0” wide X 10’ 0” high1...:
Can the LM9000 multi lock series be used in standard openings?
Resolution:
Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...: