thickness exit devices

RELATED FAQS

Question
Answer
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F, 8875-F or...
Exit alarm ALK devices are not recommended for exterior application. We do not offer water proof exit alarm ALK devices.
We have several blank trims listed in the price book to cover existing trim prep in door.  DEVICE EO TRIM   22  230EO  88  880EO   98/99  990EO or 996EO*  33A/35A Rim, 33/3...
Standard Schlage rim cylinders will fit a total thickness of door and projecting trim of 3 inches, this includes a minimum of 3/8" of engagement of the tailpiece into the exit device.  See ima...
For total thickness measurements larger than 3 inches see the special cylinder offerings in Pricebook.  Specify the part number and include the total thickness.  We do not offer the ...
Falcon Monarch XX series trims will work with Monarch 18 series exit devices.
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.
Von Duprin does not offer any of the danmark lever designs by Schlage.