Are factory finished doors and frames available from Steelcraft?
Resolution:
Factory finished painted doors are available from Steelcraft. Frames "are not available" factory finished from the factory.Doors are offered in variety of standard colors or can be finish...:
Are hospital stops approved on fire rated frames?
Resolution:
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes: singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...:
What is the part number for the rubber tip for an Ives hinge pin door stop?
Resolution:
Model 69 the part number is 09-310Model 70 & 73, the part number is WSPART.1075:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.: