templates for nd series

RELATED FAQS

Question
Answer
Warranty Statement3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warranties do not apply to P...
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.
For ND locks shipping prior to January 30, 2017, the addition of the soft durometer spacer (SDS) on August 15, 2012 did affect the installation of the lever.  Ultimately, removing th...
There are several part numbers available: Part Number Contents 09-774 SFIC driver & Spacer N523-091 SFIC driver D500-000 Spacer
The ND-Series FSIC driver is part number N523-127.
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
The ND-Series RX,  the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
As of February 2016, ND locks began shipping with a new latchbolt. The new latchbolt offers substantially improved performance in adverse door conditions (ex, with heavy door loading) andis more ro...
Prior to February 2016, using ND-Series locks on hollow metal doors required the use of latch spacers which prevent the latch from "fishtailing" (back end of latch moving from side to side). Latch ...