Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Will the 6300 work with the 55 rim?
Resolution:
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
Can the XX-V, 19-V, 24-V or 25-V extension rod be used on the bottom rod?
Resolution:
The extension rod could be used either on the top or bottom rods.:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
What is the part number for the former F588 from Monarch?
Resolution:
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.: