Installing Electromagnetic Locks on Surface Vertical Rod Doors
Resolution:
It can be installed frame side of the rods, if there is room for it on the door. Note: The holding force will be reduced when the maglock is not installed as close to the edge of the door as ...:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
What is the part number for the former F588 from Monarch?
Resolution:
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.:
Can the XX-V, 19-V, 24-V or 25-V extension rod be used on the bottom rod?
Resolution:
The extension rod could be used either on the top or bottom rods.: