ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. 
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...