Question
Answer
SURFACE MOUNTED VERTICAL ROD DEVICE
Resolution:
2227, 3327A, 3527A, 9827, 9927, 8827, 24V, 25V, 19V, XX-V, 27, 5527, 8827, 9827, 33A27, 35A27:
FIRE RATED SURFACE MOUNTED VERTICAL ROD FIRE DEVICE
Resolution:
9827-F Series ,9827-F Series, 8827-F, 2227-F:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...:
Do you need Double Egress arm to install a 4040SE on the Push Side of a door?
Resolution:
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.: