What is the mounting hole pattern on the 1260 closer?
Resolution:
The 1260 Series closers have a bolt hole (mounting pattern) of 9-1/16" horizontal x 3/4" vertical:
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
How do you identify the model of a Falcon closer?
Resolution:
To determine the SC series, measure center to center on the closer body bolt hole mounting pattern and an overall description of the closer and arm. SC91 -- 6-3/8" x 3/4" -- unique arm SC93 -- 9-1...:
How does the Von Duprin 88TP convert to an 88L?
Resolution:
Followings are the steps to convert the Von Duprin 88TP to 88L device. Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing. Recomme...:
RU strike identification for early Corbin Russwin applications.
Resolution:
The RU lock can be requested as a retrofit for early Corbin Russwin Unit locks. Several types of strikes are offered depending on the strike conditions but two are very similar with the e...:
What are the differences between the Von Duprin 47 and 48 latch assemblies?
Resolution:
The following list explains the differences between the Von Duprin 47 and 48 latch assemblies.The 47 top latche has 5/8" throw latchbolt.The 48 top latch had 3/4" throw latchbolt for devices shippe...:
How to adjust the 9847/9947 or 9848/9948 rod adjustment?
Resolution:
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...:
What is the part number for a standard Y latch?
Resolution:
The latches for the Y and F lock are not interchangeable as the hole sizes are different. Substituting any latch voids your UL and product warranty. :
Are parts still available for the Schlage interconnect G series lock?
Resolution:
The current interconnect lock, S200 series (available in levers only), will not fit into the same door preparation.:
What is the replacement for an LCN 1070?
Resolution:
The P1070 was replaced with the 1261 Rw/PA.The 1260 arm can be used as a replacement arm for the discontinued 1070.The P1070 arm can be used on a replacement 1260 body to maintain the origina...: