Question
Answer
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
Do we have an electric strike for use w/ a mortise lock w/ deadbolt for wood frame?
Resolution:
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.:
Can I use the 10-072 strike with a L400 Series lock?
Resolution:
Only the 10-079 or 10-078 strike should be used with the L400-Series. :
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
Which electric strike do I use for cylindrical locks used in a single door?
Resolution:
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application. Check the template to confirm compatibility with specific cylindrical lock model n...: