What are the TWO red SCHLAGE flashes on an AD400?
Resolution:
ONE red flash, One red flash indicates RF COM loss, the AD400 radio did not get an answer from the PIM400-485 radio or the PIM400-TD2 radio. The PIM400-485 will turn off it's radio if th...:
Does the 4600 Series (4630 4640) operator have a built in relay?
Resolution:
Yes, the 4600 Series operators have a built in ES (electric strike) relay that can be used to unlock a strike, maglock, or EL device before opening the door.:
ELECTRIC STRIKE RELAY
Resolution:
ES:
Does the 9540 Senior Swing need a separate relay board for wiring to electric locks?
Resolution:
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...: