Question
Answer
How many compression anchors are provide per jamb on DW-Series frames?
Resolution:
For compression anchor details refer to the “ANCHORING SYSTEMS” section in the Steelcraft Tech Data Manual.Anchor Quantities: • 1 compression anchor per jamb through 9"depth • ...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is the Multi Point LM9300 Series?
Resolution:
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks...:
Can the LM9000 multi lock series be used in standard openings?
Resolution:
Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...:
What are the maximum door width and height sizes?
Resolution:
Maximum nominal (overall) single door sizes are as follows:L-Series (Laminated Door)20 Gage = 3’ 0” wide X 8’ 0” high18 Gage = 4’ 0” wide X 10’ 0” high16 Gage = 4’ 0” wide X 10’ 0” high1...:
Are Securitech 8400 series lock available on the Paladin series door?
Resolution:
The following Securitech products have been tested and approved for use on Steelcraft Paladin doors:5300 series devices- 3 point surface and concealed devices7300 series devices- 3 point surface an...:
Do Steelcraft doors and frames meet Florida Building Code (FBC) requirements?
Resolution:
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...:
Do Steelcraft PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements?
Resolution:
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC 500...:
Are H-Series doors available with seamless edges?
Resolution:
For hurricane applications, seamless edges are available as an option:H-Series doors are available with optional seamed filled (HF) seam welded (HW) door edges.HE-Series doors are availab...: