steelcraft requirements for tdi

RELATED FAQS

Question
Answer
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
Standard Doors: standard inverted bottom channels will accept the following manufactures automatic door bottoms: National Guard (320) Pemko (420) Zero International (355/354)
Special (custom) option: a special/optional end channel that will support the following manufactures: National Guard (422/423/522) Pemko (443) Zero International (360/364).
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements? 3070 max flush outswing applications Zone 4 requires 120 to 170 psf.
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...
A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...