ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
Tornado shelter applications require the use of Paladin PW14-Series doors and FP14-Series frames: Tornado shelter doors are a tested system comprising of the door, frame and hardware. ...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
No. The Steelcraft H-Series hurricane door does not meet the FEMA 361 guidelines. The Paladin (PW14-Series) door does meet the FEMA 361 guidelines.
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements? 3070 max flush outswing applications Zone 4 requires 120 to 170 psf.
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
SDI 114 is no longer published as an SDI performance standard. The new SDI standard for acoustical Performance is SDI 128-09 Steelcraft does offer products that have been tested in accordance wit...
High Definition (High Def) door panel designs have deeper shadow lines than conventional CE-Series designs. CE-Series doors are available with optional High Definition (HD2 and HD2A) door panel de...
Blast and pressure resistant doors protect people and property from explosions and shrapnel. More damage is generally caused by shrapnel than the blast itself, and a properly specified and engineer...
Steelcraft Blast Resistant Assemblies meet the following Blast Test Standards:                    ...
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...
STC stands for Sound Transmission Class. An STC (Sound Transmission Class) is a single number rating system derived from measured values of sound transmission loss in accordance with ASTM E90 and...