standard lock strike stuck

RELATED FAQS

Question
Answer
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
 Mounting Posts   Part Number  Door Thickness  L583-211  1 3/8"  L583-212  1 3/4" - See note section on SL1 trim  L583-213  2...
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
Check the following: Debris in the cylinder The cylinder cap could be too loose Incorrect pinning of the cylinder The cylinder plug is not returned to the neutral position with the cylinder s...
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
To use Von Duprin mullion for something other than our standard strike, order the mullion "Blank" and prep in the field.
010055-xx is the part number for Blade Stop Shim kit for 6111 or 6113 electric strike and it must be ordered separately.  xx is for the finish callout.
The L-Series standard strike is the 10-072 and the available lip lengths are listed below.  7/8"  (Flat or straight lip) 1" 1 3/16" (Standard for 1 3/4" doors)  1 1/2" 1 3/4" 2" over 2" up...