special demisinon for MA lock

RELATED FAQS

Question
Answer
The MA lock is field reversible.  The process involves three potential steps depending on what hand is needed. Rotating latchbolt - Changes swing of lock.  ex (RH to RHR) or inswing vs outswing ...
The MA lock can be specified in a 12 or 24V DC configuration (default is 12V). Additionally, an AC power source may be used as long as a rectifier is installed in the circuit (not provided). He...
For additional details and a wiring diagram see the MA service manual page on electrical requirements here. 
The MA was launched 4/1/10 and replaced the Falcon M lock. Newer Marketing Bulletin added on 4/26/2010 (Some items not yet available!!)
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
See below for commonly requested dimensions on the MA lock.  Dimensions not found in other literature have a square around them. CL refers to "Centerline".  
Falcon does not offer an "ADA style thumbturn.
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fail Safe (EL), 12...
The MA RX features independent switches within the chassis that allow the customer to choose whether to monitor the inside or outside knob/lever.
Each switch is pre-wired to work with either normally open or normally closed systems, with color coded 5 ft long leads.
See Marketing announcement here
Solenoid: Black (2 wires) Case side RX Normally Open: Green Normally Closed: Orange Cover side RX Normally Open: Gray Normally Closed: Red Common: Yellow
Refer to the MA RX diagram here for more information.
To remove the M lock trim follow the steps below in reverse.       The M lock spanner wrench is 021415.  Although this wrench is no longer available from&n...
The thumbturn will work but the spindles sit 90 degrees off from each other (Schlage is square, Falcon is diamond).  The result is the throw will end up 10 and 2 o'clock instead of 12 and 3. 
The B520-698 cam was designed for a Schlage IC mortise cylinder (see Figure 1) to operate a Falcon MA lock, all functions except the MA381.  There is no Schlage cylinder option ...
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
Here are some of the major differences between the M and MA-Series.  Lever mounting post holes -  Locations have changed on door template.  (12 and 6 o'clock for M lock, MA lock is approx 1 and...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
Depending on the door construction the minimum stile may differ but a safe dimension would be 4-3/4".  CUSTOMER must check door construction. The pocket depth requirements of the case is 4 1/2".