solenoid plunger adjustment
”
RELATED FAQS
Question
Answer
How many thread should be showing on the solenoid plunger bushing on EL device to operate correctly?
Resolution:
The threaded bushing on the solenoid plunger requires 8-9 threads showing to operate correctly.:
Does the Inpact EL94/95 have the same solenoid as the EL devices?
Resolution:
As of 1/16/2013, the 113189-00 EL INPACT SOLENOID/PLUNGER ASSY is no longer available.:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
What could cause the Von Duprin EL solenoid not to hold when mechanism cover plate is slide over the solenoid?
Resolution:
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment. You must lengthen the rod by turning the hex nut in front of the plun...:
Solenoid on Chexit pulls back and immediately lets go and alarm goes off with red solid light.
Resolution:
The following could cause the Chexit solenoid ( devices shipped prior to 8-24-2015) pulls in then drop out with no alarm. Mechanical adjustment such as vertical rods. Disconnect t...:
Why would an electric strike not stay locked when turned upside down?
Resolution:
The Von Duprin 6000 series electric strike has a 12 or 24VDC solenoid with plunger, spring and impact washer as shown 6000 solenoid Make sure the solenoid spring and impact washer are not missin...: