Smallest width door for SRSW pair?

RELATED FAQS

Question
Answer
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
"PUSH SIDE" application:    Minimum 52" wide pair,  with neither door being less than 21" wide.   "PULL SIDE" application - For Product Shipped...
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...
When templated for 140° the 4010 will fit on a 16-1/2" door leaf MINIMUM.
The 2670 Guard X device can't be cut down to fit doors less than 3 feet.  This device is designed to fit doors 36"-48" door width.
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...