Question
Answer
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders.  Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
The Schlage small format interchangeable core rim cylinders 80-329, 80-159, 80-116, and 08-129 can accept 6 pin and 7 pin small format cores.
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
Q330-168 SFIC Tailpiece (throw member for levers) Q330-169 SFIC Tailpiece (throw member for knobs) 
UL437 is testing requirement that cylinders pass both a timed cylinder pick test and a forceful core/cylinder pull test.  We have various cylinders to meet this need, please reference our price boo...
The Schlage L9000-Series with anti-ligature trim cannot be ordered less cylinder (L cylinder suffix), but can be ordered less core (BD or J cylinder suffix). The cylinder rose dimensions change bas...