How should a Von Duprin exit device be written out for ordering?
Resolution:
To order Von Duprin exit devices, reference the "How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website. Choose "Cata...:
Why would 24-R device pop open when jiggled back and forth?
Resolution:
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt would resolve the issue. Parts to the F-24R center case...:
Can the deadlocking feature be added to a 24-R in the field?
Resolution:
If device backset is correct, replacing the device center case & center case cover with a F-24-R to add deadlocking to the latchbolt. Parts to the F-24R center case & cover can b...:
Do 25 series exit devices have a hurricane rating available?
Resolution:
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Can a 55 or 88 series device have a request to exit switch?
Resolution:
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...:
Von Duprin electrified mullions and handing details.
Resolution:
4754, 4854 and the 9854 are electrified mullions and handed as noted below: 4754 is not handed: Prepared for two 4263 monitor strikes. Use with all Von Duprin rim panic devices 4854 is han...: