Setup schagel sense remote access

RELATED FAQS

Question
Answer
The Request to Exit (RTX) switch input can be used as a remote door release.
A single-pole, single-throw switch (e.g., pushbutton switch) must be connected across the RTX input pins.
When the switch changes state (e.g., from open to closed), the CT5000 will change the state of the Strike relay.
The PIB300/PIB301 should be located as close as possible to the Access Control Panel.  Do not exceed 500 feet.
Wiring distance from the PIB300/301 to the AD300/301 locksets may be up to 1000 feet (18AWG) for Power and up to 4000 feet (24AWG) for the RS485 data lines.
See the User Guide instructions in the links below
First, perform a Factory Default Reset  Next, close the app, turn off Bluetooth (swipe up from the bottom of the screen, tap the Bluetooth icon). Turn Bluetooth back on.  Reop...