senior swing single side egress

RELATED FAQS

Question
Answer
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...
Push Side Surface Mount Senior Swing can be used with swing clear hinges, standard templating. Pull Side Surface Mount Senior Swing cannot be used, the pull arm will hit the back of door at approxi...
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
Pull Side Mount: The 4040SEL X ST-2966 is required for pull side mounting with swing clear hinges. ST-2966 template
Push Side Mount: Take the dimensions for the closer and track from centerline of swing clear hinge pin for the push side mount.
The maximum opening is 120° with the 4041/4041XP standard templating on the pull side of the door.
One Deleay Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly. If transom lights and/or sidelights are required, they must be built and installed as separate Fire Window assemb...