Schlage sfic best housing

RELATED FAQS

Question
Answer
The Schlage SFIC rim cylinder driver is part number B520-365, shown below.     Figure 1: SFIC Rim Cylinder Housing
Schlage only offers a limited number of keyways that match the BEST sections. Available in keys and cores.Specify keyway using the B suffix: AB = A, BB=B, CB=C, DB = D, DDB=DD, EB = E, FB = F, GB =...
ND locks can be extended up to 6" Extended Outside.  
Primus is only available in 6 pins in a conventional key-in-lever or full size interchangeable core designs.
The H-Series is not available with a small format interchangeable core option.
The CS200, S200, and S-Series is not available with the small format interchangeable core option.
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
Part number 80-037 is the combinated Schlage Everest small format interchangeable core and is available in the restricted Everest B Family keyways. Part number 80-036 is an uncombinated version.
Schlage Everest B keyways are restricted SFIC keyways.
There are different mortise cylinder length options depending on the cylinder type. Below is a list of available options for conventional, FSIC, and SFIC cylinders, as well as the convent...
Rim cylinder housing only for FSIC is part number 20-079.
Rim cylinder housing only for SFIC is part number 80-129.
This only applies to the full size interchangeable cores.  The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).  Simply add (-ICX) to the end o...
The Schlage small format interchangeable core rim cylinders 80-329, 80-159, 80-116, and 08-129 can accept 6 pin and 7 pin small format cores.
1 1/8" mortise cylinders fit the 650 series keyswitch.  The 650 series keyswitch when ordered with the cylinder, will come complete with the correct cylinder, cam, and any required blocki...
If blocking rings (PN 36-079) are needed, specify dimensions when ordering. See below for blocking ring (PN 36-079) dimensions.  Blocking Ring  Specify Dimension  1//8" ...
Used for installing interchangeable core housings.
See attachment that describes this tool.
Issue:  Schlage SFIC mortise cylinders have potential for the driver pins to fall out affecting the ability to lock and unlock the device.Facts: Housings manufactured between 06/01/2...
Yes. Both Schlage and Falcon SFIC mortise housings will accept 6 and 7 pin cores with no additional parts.
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into the lock and will operate t...
Warranty Statement3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warranties do not apply to P...
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system.  A keyway name may be shared between the two key fami...
Key in lever Falcon cylinders do not work in Schlage locks.  The cylinders may fit, but there are no specific tailpieces created to operate any Schlage lock. SFIC SFIC is universal so Falcon and...
   Hotel cylinder in L9000 As long as the correct cam is used (Schlage clover), a Falcon Hotel cylinder will properly function in an L9486 hotel lock.
B500 with standard cylinders How to order with the deadbolt: Door thickness over 1 3/4" to 2 1/4", specify door thickness when deadbolt is ordered Door thickness greater than 2 1/4" will req...
Verify the door thickness is 1 5/8" or greater per the pricebook.  Thin doors will force the clip off the housing.  If door thickness is correct then replace the product as needed.
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
Schlage ND-Series tailpieces for extended doors are available by only two means, but are not available to order separately. If an extended tailpiece is needed, then a complete lock will need to ...
UL437 is testing requirement that cylinders pass both a timed cylinder pick test and a forceful core/cylinder pull test.  We have various cylinders to meet this need, please reference our price boo...
The B600 (standard cylinder only) can be be specified for 1 3/8" thin doors and the appropriate parts will be supplied.  Interchangeable cores are not available for 1 3/8" thin doors.
The outside housing, B600-089, can be ordered to retrofit an existing standard cylinder B600.Description: 1 1/8” Collar (trim ring) for 1 3/8” – 1 5/8” door
There are several ways to spot differences, see Figure 1, but the easiest is to look at the face of each core. The face of both cores looks like a "figure 8".  With small format, bo...
The Schlage AL-Series SFIC locks require one (1) small format spacer (D500-000) for 7-pin cores and two (2) small format spacers for 6-pin cores.  When these spacers are not ins...
Regular Core (suffix keyway to number) Description Uncombinated Combinated 6-Pin 7-Pin 6-Pin 7-Pin Standard C646 C647 C606 C607 Best style capping CB846 CB847 CB...
The small format core throw member for the AL locks is C604-381.