Schlage NDE accept BEST SFIC
”
RELATED FAQS
Question
Answer
How do you order the ND series lock with a small format core?
Resolution:
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core:
Will Schlage locks with a BD suffix accept a BEST SFIC core?
Resolution:
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into th...:
Does the Schlage SFIC rim housings accept both 6 and 7 pin IC cores?
Resolution:
The Schlage small format interchangeable core rim cylinders 80-329, 80-159, 80-116, and 08-129 can accept 6 pin and 7 pin small format cores.:
Will the SFIC mortise housing accept both six and seven pin cores?
Resolution:
Yes. Both Schlage and Falcon SFIC mortise housings will accept 6 and 7 pin cores with no additional parts.:
How long is the ND tailpiece for a thick door?
Resolution:
Schlage ND-Series tailpieces for extended doors are available by only two means, but are not available to order separately. If an extended tailpiece is needed, then a complete lock ...:
Will Schlage make a cylinder in another vendors keyway?