schlage electric strikes
”
RELATED FAQS
Question
Answer
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
Which electric strike do I use for cylindrical locks used in a single door?
Resolution:
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application. Check the template to confirm compatibility with specific cylindrical lock model n...:
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
Is there an electric strike that will work with the 2670 Guard X?
Resolution:
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...: