Question
Answer
Which exit devices work with the AD-Series exit trims?
Resolution:
Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.:
What parts do I need to add to the bottom rod of my existing Von Duprin 8827 LBR exit device?
Resolution:
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Why is the electric E996L-FSE trim used with a Chexit CX99 exit device?
Resolution:
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...:
Does Von Duprin offer an exit device for exterior use?
Resolution:
Von Duprin now offers the Outdoor Defense (OUT) option for its 98/99 rim and 98/9927 surface vertical rod exit devices. The OUT option protects an exit device's critical operating components ...:
Can a Von Duprin 3' pushpad exit device be converted to a 4' device in the field?
Resolution:
A 3' exit device cannot be converted to a 4' exit device. You will need to replace the 3' device with a 4'. Conversely, a 4' device cannot be converted to a 3' device. Converting these exit de...: